System Components

Shipping & Returns

Shipping & Delivery

We offer fast, relaible & free shipping on all orders within the contiguous U.S. Orders are typically processed within 1–2 business days, with most deliveries arriving in 5–9 business days, depending on the product and destination. Larger items may ship via freight and require a scheduled curbside delivery. Please ensure your shipping information is accurate at checkout. For complete details, please see our Shipping Policy or contact us by phone, email, or live chat.

Returns & Refunds

Returns are accepted within 30 days of delivery for unused, uninstalled items in their original packaging.

Customer-initiated returns are subject to customer-paid return shipping and a 25% restocking fee. Defective or damaged products are not subject to a restocking fee.

For complete details, please see our Return & Refund Policy or contact us by phone, email, or live chat.

PLAN YOUR INSTALLATION

Installation & requirements

DIY 5th Gen Multi-Zone - Wall-Mounted

Check placement, routing and power requirements before choosing your installation supplies. This guide summarizes the supplied MRCOOL manual for wall-mounted multi-zone systems.

View full installation manual
Indoor placement & clearances
Indoor placement & clearances diagram from the DIY 5th Gen Multi-Zone - Wall-Mounted manual
MRCOOL manual diagram. Select image to enlarge.
  • Check the location and clearances for every wall-mounted indoor unit separately. Ceiling-cassette applications require their own indoor-unit instructions.
  • Choose a solid, level mounting surface that can carry the indoor unit, with a clear path for air circulation.
  • Allow at least 5.9 in (15 cm) above the wall-mounted unit and 4.72 in (12 cm) on each side. Mount its bottom at least 5.90 ft (1.8 m) above the floor.
  • Check the manual’s refrigerant-charge and minimum-room-area requirements for your model and mounting height. These safety limits are different from the cooling coverage estimate.
  • Plan the wall opening and piping route before fixing the mounting plate. Follow the model-specific template and instructions; protect any concealed wiring and plumbing.

Manual pp. 17, 18, 19, 20, 21

Outdoor placement & mounting
Outdoor placement & mounting diagram from the DIY 5th Gen Multi-Zone - Wall-Mounted manual
MRCOOL manual diagram. Select image to enlarge.
  • Use a firm, level base or a suitably rated wall bracket, with space for ventilation and future service.
  • Use the clearance diagram for this series. Several distances depend on which other sides are unobstructed; read each condition shown rather than applying one distance to every installation.
  • Check the unit’s mounting-foot dimensions before choosing a pad or bracket. Keep the air inlet and outlet unobstructed.
  • Plan for wind, rainfall, snow and defrost water as described in the manual. Any shelter must preserve airflow.

Manual pp. 22, 23, 24, 25

Line-set length & routing
  • Each indoor unit needs its own route back to the condenser. Your order supplies line sets according to the selections made above; a None selection does not include that run.
  • Measure the complete routed distance, including bends and the wall passage, before choosing a line-set length.
  • Check each individual run, the total connected piping and all height differences against the limits for the selected condenser and indoor combination. Do not apply a single-zone limit to this system.
  • Use the Quick Connect pipe size, refrigerant compatibility and fittings approved for the exact indoor and outdoor units. Do not assume accessories are interchangeable across series.
  • Do not cut a pre-charged line set. Plan for excess length and bend handling according to the full installation manual.
  • Keep connectors clean and capped until ready to connect. Follow the specified connection and leak-check procedures in the manual.
  • The supplied manual lists a maximum individual indoor-unit run of 75 ft (22.9 m). Check the matching outdoor configuration for its total piping and height limits; the individual-run limit is not the allowed system total.
  • For longer routes, confirm approved line-set combinations, couplers, adapters and communication-cable length before purchase.

Manual pp. 10, 12, 26, 27, 28, 29, 30, 31

Drain-hose requirements
Drain-hose requirements diagram from the DIY 5th Gen Multi-Zone - Wall-Mounted manual
MRCOOL manual diagram. Select image to enlarge.
  • Plan a continuous gravity-drain route from the indoor unit to a suitable discharge location.
  • Avoid kinks, upward loops and water traps. Keep the hose outlet out of standing water, and insulate indoor drain extensions as instructed.
  • Place the drain hose below the refrigerant piping in the bundled wall passage. The unused indoor drain outlet must remain sealed.
  • Test drainage before completing the installation. If your proposed route cannot drain by gravity, have the drainage solution confirmed before ordering additional equipment.

Manual pp. 33, 34

Electrical requirements
  • Have a licensed electrician confirm the dedicated supply circuit, grounding, protective devices and disconnect requirements for the exact outdoor unit.
  • Use the equipment nameplate and local electrical rules for final cable and protection selection. Cable sizing can change with run length, installation conditions and temperature.
  • The table below reproduces the planning values in the supplied manual. Maximum protection is a limit, not a universal instruction to fit that breaker size.
  • Electrical work is separate from the Quick Connect refrigerant-line connection. Follow the full manual and the wiring diagram on the equipment.
Outdoor-unit electrical planning values
Outdoor sizeSupply (1-phase, 60 Hz)Minimum circuit ampacityMaximum protection
18,000 BTU230V class; see nameplate16 A20 A
27,000 BTU230V class; see nameplate23 A25 A
36,000 BTU230V class; see nameplate30.5 A35 A
48,000 BTU230V class; see nameplate40 A45 A
55,000 BTU230V class; see nameplate43 A45 A

For multi-zone systems, choose the outdoor condenser size, not the sum of indoor-unit capacities. In a custom builder, use the equipment actually selected.

Manual pp. 34, 35, 36, 37, 38, 39

Tools & additional supplies
  • Plan for a level, tape measure, drill and suitable wall-hole tooling, screwdrivers, the specified wrenches or approved torque tools, and leak-detection solution.
  • Wall type, mounting location and the electrical installation determine which additional fixings and supplies are needed.
  • Electrical supply wiring, protection and disconnect components must be specified by the electrician. Confirm pad or bracket needs and any drain extension or line cover separately.
  • Compare your order’s In the box list with the manual’s packing list. Optional accessories are not automatically included.

Manual pp. 9, 10, 15, 26, 27

Planning summary based on the supplied MRCOOL manual, dated January 8, 2026. Follow the full manual, equipment nameplate and applicable installation requirements.

Need help planning your installation?

INSTALL WITH CONFIDENCE

MRCOOL DIY Installation Videos

Follow these step-by-step guides to better understand the installation process before getting started.

Complete MRCOOL DIY Installation Walkthrough

MRCOOL DIY Mini Split Installation Guide

BTU Coverage Guide

6,000 BTU
up to 200 sq. ft.
9,000 BTU
up to 400 sq. ft.
12,000 BTU
up to 550 sq. ft.
18,000 BTU
up to 800 sq. ft.
24,000 BTU
up to 1,050 sq. ft.
36,000 BTU
up to 1,550 sq. ft.

Additional factors may affect performance, including insulation, ceiling height, sun exposure, local climate, and the number of appliances in the room. For assistance, contact our Product Experts.

HELP BEFORE YOU ORDER

Product questions, answered

Answers for DIY 5th Gen Multi-Zone - Wall-Mounted .

Ask a product expert
Can I install this system myself?

This DIY series uses pre-charged Quick Connect® refrigerant line sets, so the specified installation does not require vacuuming or charging the refrigerant circuit. You still need to follow the full manual for mounting, routing, connections and testing, and meet local permit and licensing requirements.

Plan a separate line-set route, communication connection and drain route for each indoor unit.

View installation requirements

Do I need an electrician, and what power supply is required?

Have a licensed electrician confirm the dedicated power supply, grounding, disconnect and circuit protection for the exact outdoor unit. Voltage and electrical ratings vary by model and capacity; use the equipment nameplate and manual rather than a universal breaker or wire-size recommendation.

The electrical supply work is separate from connecting the pre-charged DIY line sets.

Check the electrical requirements for this series

Which line sets are included with my multi-zone system?

Your order includes the line sets you select for each air handler above. A None selection does not include a line set for that zone. The System Components summary shows each handler with its selected length so you can review the pairings before adding to cart.

Measure the full routed distance for each run, including bends and the wall passage. For a route needing couplers or an extension, contact us to confirm the correct connections, communication-cable length and model limits before ordering. Do not cut a pre-charged line set.

What else might I need for installation?

Review System Components and What’s Included for the equipment and supplies in your order. Items such as a condenser pad or wall bracket, electrical supply components, line covers and drain extensions are separate unless explicitly listed as included.

A condensate pump may be needed where gravity drainage is not possible; it is not required for every installation. Check the drainage plan and the manual before choosing accessories.

Review mounting, drainage and supplies

Can I control each room separately and use an app?

Each indoor unit has its own remote, so you can set room temperatures individually. The zones share one condenser and must use compatible operating modes: the system cannot heat one room while cooling another at the same time.

For app control, set up each indoor unit using its supplied smart-controller instructions and compatible Wi-Fi network.

How do I register my system and check its warranty?

Keep your purchase invoice and record the equipment model and serial numbers. Use MRCOOL’s warranty registration page to register your equipment.

MRCOOL’s published standard limited warranty for this series does not require registration. Coverage still depends on the warranty’s installation, use and other conditions.

Optional extended coverage has separate enrollment, costs and conditions. Standard product registration alone does not enroll you in a paid extended-coverage program.

Read MRCOOL’s warranty terms for this series . Coverage and exclusions vary by model and generation.

When will my order ship, and how is it delivered?

Orders are typically processed within 1–2 business days, followed by an estimated 4–7 business days in transit. Backorders and carrier delays can extend these estimates. Tracking is emailed after shipment.

Larger equipment commonly ships by freight with curbside delivery to an accessible location. Standard delivery does not include moving equipment inside or installation. Contact us before ordering if your address has restricted truck access.

Read the full Shipping Policy

View the full installation manual