We offer fast, relaible & free shipping on all orders within the contiguous U.S. Orders are typically processed within 1–2 business days, with most deliveries arriving in 5–9 business days, depending on the product and destination. Larger items may ship via freight and require a scheduled curbside delivery. Please ensure your shipping information is accurate at checkout. For complete details, please see our Shipping Policy or contact us by phone, email, or live chat.

Returns & Refunds

Returns are accepted within 30 days of delivery for unused, uninstalled items in their original packaging.

Customer-initiated returns are subject to customer-paid return shipping and a 25% restocking fee. Defective or damaged products are not subject to a restocking fee.

For complete details, please see our Return & Refund Policy or contact us by phone, email, or live chat.

PLAN YOUR INSTALLATION

Installation & requirements

DIY Hyper Heat Single-Zone

Check placement, routing and power requirements before choosing your installation supplies. This guide summarizes the supplied MRCOOL manual for this single-zone series.

View full installation manual
Indoor placement & clearances
Indoor placement & clearances diagram from the DIY Hyper Heat Single-Zone manual
MRCOOL manual diagram. Select image to enlarge.
  • Choose a solid, level mounting surface that can carry the indoor unit, with a clear path for air circulation.
  • Allow at least 5.9 in (15 cm) above the wall-mounted unit and 4.72 in (12 cm) on each side. Mount its bottom at least 5.90 ft (1.8 m) above the floor.
  • Check the manual’s refrigerant-charge and minimum-room-area requirements for your model and mounting height. These safety limits are different from the cooling coverage estimate.
  • Plan the wall opening and piping route before fixing the mounting plate. Follow the model-specific template and instructions; protect any concealed wiring and plumbing.

Manual pp. 15, 16, 18

Outdoor placement & mounting
Outdoor placement & mounting diagram from the DIY Hyper Heat Single-Zone manual
MRCOOL manual diagram. Select image to enlarge.
  • Use a firm, level base or a suitably rated wall bracket, with space for ventilation and future service.
  • Use the clearance diagram for this series. Several distances depend on which other sides are unobstructed; read each condition shown rather than applying one distance to every installation.
  • Check the unit’s mounting-foot dimensions before choosing a pad or bracket. Keep the air inlet and outlet unobstructed.
  • Plan for wind, rainfall, snow and defrost water as described in the manual. Any shelter must preserve airflow.

Manual pp. 20, 21, 22

Line-set length & routing
  • This guide applies to the 25 ft nominal complete-system package. If your product page offers a different selected length, confirm the actual order contents above.
  • Measure the complete routed distance, including bends and the wall passage, before choosing a line-set length.
  • Use the Quick Connect pipe size, refrigerant compatibility and fittings approved for the exact indoor and outdoor units. Do not assume accessories are interchangeable across series.
  • Do not cut a pre-charged line set. Plan for excess length and bend handling according to the full installation manual.
  • Keep connectors clean and capped until ready to connect. Follow the specified connection and leak-check procedures in the manual.
  • The supplied manual lists a maximum connected pipe length of 75 ft (22.9 m). Maximum elevation varies by capacity: 12,000 BTU: 49.2 ft (15 m); 18,000 BTU: 65.6 ft (20 m).
  • A permitted piping limit does not establish that any particular extension kit fits this series. Confirm approved extension options before changing the included run.

Manual pp. 23, 24, 25, 27

Drain-hose requirements
Drain-hose requirements diagram from the DIY Hyper Heat Single-Zone manual
MRCOOL manual diagram. Select image to enlarge.
  • Plan a continuous gravity-drain route from the indoor unit to a suitable discharge location.
  • Avoid kinks, upward loops and water traps. Keep the hose outlet out of standing water, and insulate indoor drain extensions as instructed.
  • Place the drain hose below the refrigerant piping in the bundled wall passage. The unused indoor drain outlet must remain sealed.
  • Test drainage before completing the installation. If your proposed route cannot drain by gravity, have the drainage solution confirmed before ordering additional equipment.

Manual pp. 29, 30

Electrical requirements
  • Have a licensed electrician confirm the dedicated supply circuit, grounding, protective devices and disconnect requirements for the exact outdoor unit.
  • Use the equipment nameplate and local electrical rules for final cable and protection selection. Cable sizing can change with run length, installation conditions and temperature.
  • The table below reproduces the planning values in the supplied manual. Maximum protection is a limit, not a universal instruction to fit that breaker size.
  • Electrical work is separate from the Quick Connect refrigerant-line connection. Follow the full manual and the wiring diagram on the equipment.
Outdoor-unit electrical planning values
Outdoor sizeSupply (1-phase, 60 Hz)Minimum circuit ampacityMaximum protection
12,000 BTU208/230V15 A15 A
18,000 BTU208/230V19 A25 A

Manual pp. 30, 31, 32

Tools & additional supplies
  • Plan for a level, tape measure, drill and suitable wall-hole tooling, screwdrivers, the specified wrenches or approved torque tools, and leak-detection solution.
  • Wall type, mounting location and the electrical installation determine which additional fixings and supplies are needed.
  • Electrical supply wiring, protection and disconnect components must be specified by the electrician. Confirm pad or bracket needs and any drain extension or line cover separately.
  • Compare your order’s In the box list with the manual’s packing list. Optional accessories are not automatically included.

Manual pp. 9, 14, 23

Planning summary based on the supplied MRCOOL manual, dated January 8, 2026. Follow the full manual, equipment nameplate and applicable installation requirements.

Need help planning your installation?

INSTALL WITH CONFIDENCE

MRCOOL DIY Installation Videos

Follow these step-by-step guides to better understand the installation process before getting started.

Complete MRCOOL DIY Installation Walkthrough

MRCOOL DIY Mini Split Installation Guide

BTU Coverage Guide

6,000 BTU
up to 200 sq. ft.
9,000 BTU
up to 400 sq. ft.
12,000 BTU
up to 550 sq. ft.
18,000 BTU
up to 800 sq. ft.
24,000 BTU
up to 1,050 sq. ft.
36,000 BTU
up to 1,550 sq. ft.

Additional factors may affect performance, including insulation, ceiling height, sun exposure, local climate, and the number of appliances in the room. For assistance, contact our Product Experts.

COMPARE

MRCOOL DIY 18K BTU Systems

Choose a BTU size to compare models here.

BTU

Covers up to 800 sq. ft.

HELP BEFORE YOU ORDER

Product questions, answered

Answers for DIY Hyper Heat Single-Zone.

Ask a product expert
Can I install this system myself?

This DIY series uses pre-charged Quick Connect® refrigerant line sets, so the specified installation does not require vacuuming or charging the refrigerant circuit. You still need to follow the full manual for mounting, routing, connections and testing, and meet local permit and licensing requirements.

View installation requirements

Do I need an electrician, and what power supply is required?

Have a licensed electrician confirm the dedicated power supply, grounding, disconnect and circuit protection for the exact outdoor unit. Voltage and electrical ratings vary by model and capacity; use the equipment nameplate and manual rather than a universal breaker or wire-size recommendation.

The electrical supply work is separate from connecting the pre-charged DIY line sets.

Check the electrical requirements for this series

What line-set length comes with this system, and can I change it?

The listed line-set length for this complete system is 25 ft. Confirm the included length in the product options and What’s Included details before ordering.

Measure the complete routed distance, including bends and the wall passage. If you need a different length, contact us to confirm the compatible line set, connections and communication cable for this exact model. Do not cut a pre-charged line set.

What else might I need for installation?

Review System Components and What’s Included for the equipment and supplies in your order. Items such as a condenser pad or wall bracket, electrical supply components, line covers and drain extensions are separate unless explicitly listed as included.

A condensate pump may be needed where gravity drainage is not possible; it is not required for every installation. Check the drainage plan and the manual before choosing accessories.

Review mounting, drainage and supplies

Can I use a remote control and a phone app?

The system includes a handheld remote and a smart/Wi-Fi controller kit. Follow the controller instructions supplied with your exact model for the correct app, network requirements and pairing steps. The app and controller can differ between series.

How do I register my system and check its warranty?

Keep your purchase invoice and record the equipment model and serial numbers. Use MRCOOL’s warranty registration page to register your equipment.

Read MRCOOL’s warranty terms for this series . Coverage and exclusions vary by model and generation.

When will my order ship, and how is it delivered?

Orders are typically processed within 1–2 business days, followed by an estimated 4–7 business days in transit. Backorders and carrier delays can extend these estimates. Tracking is emailed after shipment.

Larger equipment commonly ships by freight with curbside delivery to an accessible location. Standard delivery does not include moving equipment inside or installation. Contact us before ordering if your address has restricted truck access.

Read the full Shipping Policy

View the full installation manual

Customers also bought

    Customers rate us 4.96/5 based on 75 reviews.